• Ampe kìm Fluke 317/319

  • Đăng ngày 04-08-2016 03:23:20 AM - 1381 Lượt xem
  • Giá bán: Liên hệ

  • The Fluke 317 and 319 are designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements up to 1000 A (319) in tight cable compartments.


Số lượng
  • "Unique 40A high-precision low current measurement--0.01A high-resolution, 1.6% high-precision measurement"
  • "The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces"
  • "The large backlight display facilitates readings in dark environments"
  • Starting current (inrush) functionality (319) allows measurement of the starting current of electrical and lighting equipment, for example. (319)
  • Current frequency measurement
  • Precision down to 0.01A and 0.1V
  • 1000A/600A AC/DC current measurement (319/317)
  • 600V AC/DC voltage measurement
  • 4000Ω resistance measurement
  • Continuity beeper
  • Auto off function enhances battery life, meaning the instrument can work when you need it screen store ‘hold’ function for capturing a measurement result on the screen
  • One year warranty
General Specifications
Digital Display
   6000 count resolution
Low Battery Indication
   Displays a signal when the batteries are below their required voltage
Power Source
   Three AAA IEC LR03 batteries
Jaw opening
   1.45 in (37 mm)
Dimensions (L x W x H)
   234 x 74 x 34.8 mm
Weight
   approximately 13.5 oz (384 g) (batteries included)
Automated measurement
   Available in Ohms
Safety
   CE
   EN/IEC 61010-1 and IEC 61010-2-032
   Installation type III, 600V working environment

 

317 Electrical Specifications
Current AC
Range  40.00 A, 600.0 A
Resolution  0.01 A, 0.1 A
Accuracy  1.6% ± 6 digit (50-60 Hz) {40 A}
   2.5% ± 8 digit (60-500 Hz) {40 A}
   1.5% ± 5 digit (50-60 Hz) {600 A}
   2.5% ± 5 digit (60-500 Hz) {600 A}
Crest Factor add 2% into spec for CF > 2  3.0 Max @ 500 A, 2.5 Max @ 600 A
AC response  rms
Current DC
Range  40.00 A, 600.0 A
Resolution  0.01 A, 0.1 A
Accuracy  1.6% ± 6 digit (40 A)
   1.5% ± 5 digit (600 A)
Voltage AC
Range  600.0 V
Resolution  0.1 V
Accuracy  1.5% ± 5 digit (20-500Hz)
AC response  rms
Voltage DC
Range  600.0 V
Resolution  0.1 V
Accuracy  1% ± 4 digit
Resistance
Range  400.0 Ω, 4000 Ω
Resolution  0.1 Ω, 1 Ω
Accuracy  1% ± 5 digit
Continuity
   ≤ 30 Ω
Inrush
Integration time  N/A
Frequency
Range  N/A
Accuracy  N/A
Trigger Level  N/A

 

319 Electrical Specifications
Current AC
Range  40.00 A, 600.0 A, 1000 A
Resolution  0.01 A, 0.1 A, 1 A
Accuracy  1.6% ± 6 digit (50-60 Hz) {40 A}
   2.5% ± 8 digit (60-500 Hz) {40 A}
   1.5% ± 5 digit (50-60 Hz) {600/1000 A}
   2.5% ± 5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2  3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response  rms
Current DC
Range  40.00 A, 600.0 A, 1000 A
Resolution  0.01 A, 0.1 A, 1 A
Accuracy  1.6% ± 6 digit (40 A)
   1.5% ± 5 digit (600/1000 A)
Voltage AC
Range  600.0 V
Resolution  0.1 V
Accuracy  1.5% ± 5 digit (20-500Hz)
AC response  rms
Voltage DC
Range  600.0 V
Resolution  0.1 V
Accuracy  1% ± 4 digit
Resistance
Range  400.0 Ω
   4000 Ω
Resolution  0.1 Ω
   1 Ω
Accuracy  1% ± 5 digit
Continuity
   ≤ 30 Ω
Inrush
Integration time  100 ms
Frequency
Range  5.0 - 500.0 Hz
Accuracy  0.5% ± 5 digit
Trigger Level  10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A

All precisions refer to 73°F ± 41°F (23°C ± 5°C)

Less than 64°F and greater than 82°F (18°C and greater than 28°C) 

 

Environmental Specifications
Operating Temperature
   14°F to 122°F (-10°C to 50°C)
Storage Temperature
   -40°F to 140°F (-40°C to 60°C)
Operating Humidity
   Non condensing (< 50°F) (< 10°C)
   90% RH (50°F to 86°F) (10°C to 30°C)
   75% RH (86°F to 104°F) (30°C to 40°C)
   45% RH (104°F to 122°F) (40°C to 50°C)
   (Without Condensation)
Operating Altitude
   1 mile (2000 meters) above mean sea level
Storage Altitude
   7 miles (12,000 meters) above mean sea level
IP Rating
   IP40
Vibration Requirements
   Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop Test Requirements
   3 ft (1 m) drop test, six sides, oak floor
EMI, RFI, EMC
   Instrument unspecified for use in EMC field ≥ 0.1 V/m
Temperature Coefficients
   0.1x (specified accuracy)/°C
   (<64°F or > 82° F)
   (<18°C or > 28°C)

 