• 5649 / 5650 Type R and Type S Thermocouple Standards

  • Đăng ngày 06-07-2017 12:41:45 AM - 273 Lượt xem
  • Giá bán: Liên hệ

  • Made from the finest platinum and platinum-rhodium alloy, these type R thermocouples and type S thermocouples cover a temperature range of 0 °C to 1450 °C with uncertainties as good as 0.15 °C over most of that range. With four different models for each type, we have the type R thermocouple and type S thermocouple to fit your application.

    Eight models to fit any type R or S thermocouple application

    • Designed by the Fluke Calibration primary temperature standards design team
    • Two sizes available, each with or without reference junction
    • Uncalibrated accuracy is the greater of ±0.6°C or ±0.1% of reading


Số lượng

The measuring junction of both the 5649 and the 5650 is encased in a 0.25-inch (6.35 mm) alumina sheath that can be ordered in lengths of 20 or 25 inches (50.8 or 63.5 cm) to fit the specific requirements of your application. A reference, or “cold," junction may also be ordered. The reference junction uses a stainless steel sheath and is 8.25 inches long (21 cm) by 0.188 inches in diameter (4.8 mm). The thin diameter minimizes the immersion depth needed, but the extra length ensures you can get all the immersion you like.

Special tin-plated, solid-copper connecting wires with ultra-low EMF properties are used to help retain the integrity of your measurement junction where the probe attaches to your micro voltmeter or Hart Black Stack.

Each probe comes from a spool of wire that has been sample tested using fixed-point standards to ensure uncertainties less than 0.5 °C up to 1100 °C. From 1100 °C to 1450 °C, the uncertainty increases linearly to 3.0°C. If you need greater accuracy, order an individual calibration with fixed-point standards to reduce uncertainties to ± 0.15 °C up to 962°C, ± 0.25 °C up to 1100 °C, and increasing linearly to ± 2.0 °C at 1450 °C.

The probe assembly can be easily disassembled for performing your own bare-wire calibrations

Specifications

Range 0 °C to 1450 °C
Type Platinum/13 % Rhodium vs. platinum (type R)
Platinum/10 % Rhodium vs. platinum (type S)
Calibration Optional fixed point calibration uncertainties
(k=2): ± 0.15 °C up to 962 °C,
increasing linearly to ± 2.0 °C at 1450 °C
Hot Junction
Sheath Dimensions
6.35 mm (0.25 in) diameter;
see Ordering Information for lengths
Reference Junction Sheath Dimensions 4.8 mm dia. x 210 mm long (0.188 x 8.25 in)
Long-Term Stability ± 0.5 °C to 1100 °C
± 2.0 °C to 1450 °C (over one year depending on usage)
Short-Term Stabilities ± 0.2 °C to 1100 °C
± 0.6 °C to 1450 °C
Immersion At least 152 mm (6 in) recommended
Protective Case Model 2609 case included
Weight 1 kg (2 lb)

 